Plasticized PVC Compounds
for General Purpose Electrical Applications |
| |
Specific
Gravity |
Tensile
Strength |
Elongation
at Break |
Shore (A)
Hardness (15") |
Cold flex
Temperature |
Volume
Resistivity |
Exercise
Temperature |
V.D.E.
0207/86 |
| Type |
Applications |
Test Method
U.M. |
ASTM D 792
g/cm |
ASTM D 638
kg/cm |
ASTM D 638
% |
ASTM D
2240 |
ASTM D
1043 C |
20 C |
C |
|
| RC/86/3 |
Primary & secondary
insulation sheeting |
1.49 |
170 |
300 |
88 |
-25 |
8x10 |
80 |
YM 3 |
| RC/86/2 |
Primary & secondary
insulation sheeting |
1.48 |
170 |
340 |
88 |
-25 |
7x10 |
80 |
YM 3 |
| RC/92 |
Primary insulation |
1.38 |
230 |
320 |
94 |
-15 |
6x10 |
80 |
YM 5 |
| RC/94/T |
High speed insulation for
telephone cable |
1.31 |
220 |
300 |
94 |
-18 |
1x10 |
70 |
|
| RC/76/1 |
Sheeting |
1.45 |
145 |
340 |
81 |
-30 |
3x10 |
70 |
YM 2 |
| RC/75 |
Sheeting |
1.38 |
230 |
320 |
94 |
-15 |
6x10 |
80 |
YM 5 |
| RC/78 |
Primary & secondary
insulation / sheeting for glossy cable |
1.26 |
180 |
370 |
78 |
-30 |
5x10 |
70 |
YM 2 |
| RC/83 |
Primary & secondary
insulation / sheeting for glossy cable |
1.34 |
180 |
320 |
83 |
-30 |
6x10 |
70 |
YM 1 |
| RC/75/K |
Coaxial sheeting / further
applications in building industry |
1.34 |
180 |
320 |
83 |
-30 |
6x10 |
70 |
|
| RC/82/K |
Coaxial cable |
1.35 |
180 |
360 |
82 |
-30 |
5x10 |
70 |
|
| RC/80/C |
Transparent cable |
1.25 |
180 |
320 |
80 |
-30 |
|
70 |
YI 1 |
|
Technical information
contained is based on Rokyplast general experience and
is given in good faith but Rokyplast is not responsible
for factors or events outside its knowledge or control. |